Accent 1400 is a speech-generating device that enhances communication for individuals with speech and language impairments. This device and its language programs enable the user to engage in conversation, search for information, express opinions, and share feelings. This manual describes how to safely use and maintain the device.
| Scan below to open the Empower Manual | Scan below to open the NuVoice Manual |
|
|
Safety Guidelines
Device Safety
Note: The following safety guidelines apply only to devices purchased from PRC-Saltillo or a subsidiary of PRC-Saltillo.
Emergencies
This device is not intended to be an emergency call device or sole communication aid.
Modifications
Do not attempt to modify the device, module, or any accessories. Modifications could create a safety hazard and make the equipment inoperative.
Contaminants
To prevent ingestion of bacteria, dust, and dirt, do not allow the user to chew on the product.
Cleaning, Maintaining, and Servicing
Do not service or maintain the device while in use. Disconnect the charger and turn off the device before cleaning.
If the device, module, or an accessory is damaged, call Service for assistance. Do not attempt to make repairs yourself.
Accessories
Do not use accessories, detachable parts, or materials not described in the manual.
Do not use accessories, detachable parts, or materials in any other way than described in the manual.
Mounting and Positioning
A qualified person should analyze positioning to prevent repetitive stress injuries to the user.
A qualified person should install and adjust any mounts, including switch mounts. Failure to install the mounting system according to the manufacturer's instructions may result in an injury to the user.
Do not place the device with an eye tracking or head tracking module attached where it is difficult to operate or difficult to disconnect from the charger.
Ensure hands are positioned on the back side of the kickstand and kept clear of the gap between the stand and the device to prevent pinching.
If the stand is removed, it becomes a potential hazard for poking an eye.
Vision and Hearing
The communication partner should ensure that the user takes frequent breaks to avoid eye strain.
Consult your vision care provider about device positioning considerations for the user.
Excessive volume or sound pressure level when using earphones or headphones can cause hearing loss over extended periods of time. Set the volume to a low level and increase it only enough that you can hear comfortably.
Ports and Connectors
Keep ports and connectors clean to maximize the service life of the device. Dirty cable connectors transfer contamination to the mating connector on the device and may degrade performance.
If the device has been exposed to water, each USB port must be completely dry before a USB cable is inserted into it. To remove moisture from the USB ports, shake the device several times with each USB port facing downward, and then use a microfiber cloth to wipe the device dry. You should then check the USB port area again. If moisture is still visible in any USB port, repeat the shaking and drying procedure.
Do not try to force a connector into a port. Be sure to insert the connector into the correct port and that the connector is turned so that it matches the orientation of the port.
Small Parts, Cords, Cables, and Straps
Cords, cables, and straps are potential entanglement or strangulation hazards. Consider this prior to placing these items with device users.
On a regular basis, visually inspect cables, cords, and connectors for damage or wear, especially where they are subject to extra stress. Cables and cords can become frayed or damaged from heavy use or with age. For example, a frayed cable could cause a battery charger/power adapter to short-circuit, posing a hazard to the user. If any cable, cord, or connector is damaged or worn, call Service for a replacement.
When unplugging a cable or cord, grasp the connector instead of the cable or cord itself to avoid damage or wear.
Always use cables, for charging or transferring vocabulary files, according to the instructions in the manual.
The stylus is a potential hazard for poking an eye.
If you are installing a head tracking or eye tracking module, the loose screws can be a choking hazard.
Small parts and loose adapters can present a choking or other hazard.
Damage
Do not use the device if the screen is cracked or broken.
Do not use an eye tracking or head tracking module if the lens is cracked or broken.
Interference
When operating this device in a medical environment, do not use it with any product that is not medically approved. Follow all rules for appropriate wireless device use.
Do not use the device or module close to sources of RF/RFID radiation or you may encounter interference. Move away, if possible, from the source of the interference.
Water
If the device has been exposed to water, each USB port must be completely dry before a USB cable is inserted into it. To remove moisture from the USB ports, shake the device several times with each USB port facing downward, and then use a microfiber cloth to wipe the device dry. You should then check the USB port area again. If moisture is still visible in any USB port, repeat the shaking and drying procedure.
The device is intended for use in normal communication situations. It is not waterproof. Do not spray or splash liquid directly on the device and use extreme caution when using it around water. As with most electronic devices, you should never use the device when you are actually in the water (for example, a pool or bath).
Heat
Do not place the device or module in an appliance such as a microwave or oven, near an open flame, or on or near a source of heat such as a stove or heater.
Do not leave the device or module in a hot vehicle for a prolonged period.
Batteries and Charging
Use only the battery charger provided with this device.
Do not place the device where it is difficult to operate or difficult to disconnect from the charger.
Always follow the instructions in this manual when charging the device.
Do not insert any object into the charging port. This can result in damage to the port.
To avoid electric shock and damage to the device, do not charge the device while it is wet or in an area where it could get wet. Do not handle the device, charger, or cords with wet hands.
Locate the device in a safe, dry location while charging. Do not charge the device outdoors.
Keep the charger away from water and do not allow water or any other liquid to spill on it.
If the charger or charger cord is damaged, call Service for a replacement.
Environment
Do not take the device into an oxygen-rich environment (operating room, oxygen tent, etc.).
Do not use the system in an environment in which explosive or flammable gases could be present.
Touching the Surface
While the device is charging, touching the surface of the device with broken skin may aggravate a wound.
While the device is charging, high-risk groups should not touch the surface if there is a chance of burning the skin.
Implantable Medical Devices
A minimum of 6 inches should be maintained between a handheld wireless device and an implantable medical device, such as a pacemaker, implantable cardioverter defibrillator, vagus nerve stimulator, shunt, or stent, to avoid potential magnetic interference with the medical device. A person who has an implantable medical device:
should always keep the device a minimum of 6 inches from their implantable medical device;
should not carry the device in a breast pocket;
should move the device away from themselves if they suspect it is interfering with the implantable medical device;
should read and follow the directions from the manufacturer of the implantable medical device.
If you have any questions about using the wireless device with an implantable medical device, consult your health care provider.
Software/App Safety
The software is not intended to be an emergency call app or a sole communication aid.
Use the software safely while texting. Do not text while performing another task or activity.
The communication partner should ensure that the user takes frequent breaks to avoid eye strain.
Consult your vision care provider about positioning the device for the user to view the software.
When adjusting volume in the software, excessive volume or sound pressure level when using earphones or headphones can cause hearing loss over extended periods of time. Set the volume at a low level and increase it only enough that you can hear comfortably.
If the software stops functioning, contact the Service department.
Eye Tracking Safety
Note: The following safety guidelines apply only to devices with an attached eye tracking module purchased from PRC-Saltillo or a subsidiary of PRC-Saltillo.
Fatigue
While the user is getting used to eye tracking, take frequent breaks to rest the user’s eyes and relax his or her concentration.
Some people may experience a certain amount of fatigue (due to intentional eye focusing and hard concentration) or even a dryness of the eyes (due to less frequent blinking) when first getting used to eye tracking. If you are experiencing fatigue or dry eyes, start off slowly and limit the length of your eye tracking sessions to your comfort level. Consult a medical professional regarding moisturizing eye drops, which may be helpful to combat dryness.
Seizures
Some people may have epileptic seizures triggered by light flashes or patterns. This may occur while presented with successive pictures or video material, even if they have never had a seizure before. Observe the individual using the system. Move the person away from the system immediately and consult a physician if the individual shows the following or similar symptoms: involuntary movements, disorientation, convulsions, loss of awareness, or altered vision.
Infrared Emissions
Eye tracking systems use infrared (IR) technology. Certain medical devices are susceptible to disturbance by IR emissions. Do not use the eye tracking system when in the vicinity of such susceptible medical devices. If you have questions about the susceptibility of a medical device, consult the manufacturer of the medical device or your health care provider.
If you have questions about the susceptibility of a medical device to the infrared technology that is part of your eye tracking system, consult the manufacturer of the medical device or your health care provider.
Compliance Information
Note: The device hardware information in this section applies only to devices purchased from PRC-Saltillo or a subsidiary of PRC-Saltillo.
Federal Communications Commission (FCC) Warning
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
this device may not cause harmful interference, and
this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
Innovation, Science and Economic Development Canada (ISED) Warning
This device complies with Innovation, Science and Economic Development Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux Innovation, Sciences et Développement économique Canada ( ISDE ) applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur del'appareil doit accepter tout brouillage radioélectrique subi, même si lebrouillage est susceptible d'en compromettre le fonctionnement.
FCC RF Radiation Exposure and SAR Statements
This device has been tested for body-worn Specific Absorption Rate (SAR) compliance and is designed to meet the requirements for exposure to radio waves established by the Federal Communications Commission (USA). These requirements set a SAR limit of 1.6 W/kg averaged over one gram of tissue. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End user must follow the specific operating instructions for satisfying RF exposure compliance.
Wireless Communications Equipment
Wireless communications equipment such as wireless home network devices, mobile phones, cordless telephones and their base stations, and walkie-talkies can affect this device and should be kept a least six inches away from the device.
Limitation of Intended Use, Third Parties, and Data Loss
PRC-Saltillo does not warrant any functionality of this speech generating device outside the terms of its express warranty relating to the intended use of speech generation. PRC-Saltillo does not warrant any third-party software, nor is it responsible for any injury, damage or claims arising from the function or malfunction of any third-party technology, websites, products, and software. Additional uses may require further clinical determinations beyond the scope of an evaluation for speech generation devices.
PRC-Saltillo assumes no responsibility for any loss or claims by third parties which may arise through the use of this product.
PRC-Saltillo assumes no responsibility for any damage or loss caused by the deletion of data as a result of malfunction repairs or battery replacement. Be sure to back up all important data on other media (computer) to protect against its loss.
Intended Purpose
This product augments communication for an individual with speech/language impairment. This product and its language programs give the user the ability to initiate conversation, seek information, state opinions, and share feelings. Depending on the hardware model, it can be hand-held, used with a table stand, or mounted to a wheelchair; and can be accessed by using the touchscreen, an available eye tracking system or head tracking system, or a variety of available switch accessories. This product does not incorporate in any way medicinal substances, human blood or plasma derivatives, nor is it manufactured using tissues of animal origin.
Indications and Contraindications
Indication: This product augments communication for an individual with speech/language impairment.
Contraindication: This product is not intended to be an emergency call device or sole communication aid.
Existing Application Risks
No existing application risks are known.
Expected Service Life
The expected service life of the device, battery charger, and accessories is five years. If you dispose of your device, battery charger, or accessories, please dispose of them in accordance with your local, state, and/or country electronic recycling laws.
Intended Operators
The individual using the product to communicate, the individual’s communication partner, and/or the person changing settings, maintaining software files, etc., are the intended operators. The text and visual aids in the manual will help these operators achieve the intended use.
Expected Position of Operators
In normal use, the device is expected to be within 12 to 14 inches of the individual’s body. The distance will vary according to whether the device is hand-held or mounted on a wheelchair or table.
Special Skills, Training, or Knowledge Required
No special skills or training are required to operate or maintain the device or software. The text and visual aids in this manual will help the operators acquire the knowledge to achieve the intended use.
Instructions for Use
All functions of the product are safe for use by the user. For best results, follow the instructions in the manual.
There is no need to turn the device or amplifier off when using the device on a daily basis. It is recommended to restart the device once per week and put it to sleep daily.
To report any serious incident associated with the device, contact PRC-Saltillo and your national authority. For information on cleaning, see the user manual.
Instructions for Storage
If you will be leaving the device in storage for a long period of time, turn the device and amplifier off. Devices in storage must be charged every six months.
Explanation of Symbols on PRC-Saltillo Devices, Accessories, or Packaging
![]()
The device is Federal Communications Commission (FCC)-compliant.
The device conforms to European Union health, safety, and environmental standards.
The device conforms to the requirements of the UK MDR 2002.
The device complies with Innovation, Science and Economic Development Canada license-exempt RSS standard(s).
The entire device and accessories, excluding the adapter, are type BF applied parts. “Applied part” refers to the part of the device with which the user comes into physical contact when using it for its intended function.
The device complies with applicable ACMA technical standards for telecommunications, radiocommunications, EMC, and EME.
Caution! Use caution when operating the device to avoid undesirable consequences.
The device emits generally elevated, potentially hazardous, levels of non-ionizing electromagnetic radiation.
Recycle electronic equipment. Do not throw the device in the trash.
IP__
The device is protected against ingress of solid objects and water.
Keep dry. The device needs to be protected from moisture.
The range of temperatures to which the device can be exposed while in use, transport, or storage.
The range of humidity to which the device can be exposed while in use, transport, or storage.
The range of atmospheric pressure to which the device can be safely exposed while in use, transport, or storage.
Refer to the instruction manual.
Consult the instructions for use or consult the electronic instructions for use.
The device employs Bluetooth wireless technology.
The device model number.
The device serial number.
The date of manufacture of the device and the name and address of the manufacturer.
Indicates a medical device.
Authorized Representatives (International)
Manufacturer and Headquarters
Prentke Romich Company
1022 Heyl Rd
Wooster, OH 44691 USA
Tel.: +1 330 262-1984 · +1 800 262-1984
Fax: +1 330 262-4829
Email: info@prentrom.com
Website: prc-saltillo.com
Canadian Operations
PRC-Saltillo Canada
PO Box 10102 Stn Main
Airdrie, AB T4A 0H4
Tel: +1 (647) 977-9626
Toll Free: 1 (800) 944-6564
Fax: +1 (855) 209-9055
Email: sales@prc-saltillo.ca
Website: prc-saltillo.ca/
EU Authorised Representative
Prentke Romich GmbH, A PRC-Saltillo Company
Karthäuserstr. 3
D-34117 Kassel Germany
Tel.: +49 (0) 561 7 85 59-0
Fax: +49 (0) 561 7 85 59-29
Email : info@prentke-romich.de
Website: prentke-romich.de/
EU Importer
Prentke Romich GmbH
Karthäuserstr. 3
D-34117 Kassel Germany
Tel.: +49 (0) 561 7 85 59-0
Fax: +49 (0) 561 7 85 59-29
Email: info@prentke-romich.de
Website: prentke-romich.de/
UK Responsible Person and UK Importer
Liberator Limited
Glenside Business Park
West Pinchbeck, Spalding, Lincolnshire
PE11 3SA United Kingdom
Tel.: +44 (0) 1733 370 470
Fax: +44 (0) 1476 552 473
Email: info@liberator.co.uk
Website: liberator.co.uk/
Swiss Authorized Representative
Inspera GmbH
Thunstrasse 64 | CH-3110 Münsingen Switzerland
Tel.: +41 31 819 74 60
Mobile: +41 79 435 53 09
Swiss Importer
Active Communication AG
Sumpfstrasse 28 | CH-6312 Steinhausen Switzerland
paraplegie.ch/activecommunication/de/
Australian Sponsor
Liberator Pty Ltd, A PRC-Saltillo Company
Suite 1.02, Level 1, 8 Parkview Drive
Sydney Olympic Park NSW 2124 Australia
Tel.: +61 (02) 9124 9945
Fax: +61 (0) 8 8211 7733
Email: info@liberator.net.au
ABN: 33 123 040 442
Website: liberator.net.au/
Singapore Registrant
PRC-Saltillo Singapore Pte. Ltd.
3791 Jalan Bukit Merah #05-23
E-Centre at Redhill Singapore 159471
Tel.: +65 6881 6133
Email: singapore@prc-saltillo.sg
Website: prc-saltillo.sg
Indian Authorized Agent
Avaz, LLC, A PRC-Saltillo Company
01C, 1st Floor
IIT Madras Research Park
Kanagam Road
Taramani, Chennai, Tamil Nadu 600113
Tel: +1 (650) 300-4904
Tel: +91 63603 12082
Email: hello@avazapp.com
Website: avazapp.com
Copyright and Trademarks
United States
©2026 PRC-Saltillo. Non-commercial reprint rights for clinical or personal use granted with inclusion of copyright notice. Commercial use prohibited; may not be used for resale. Contact PRC-Saltillo for questions regarding permissible uses.
AAC Language Lab®, AAC Learning Journey®, Accent®, AeroSwitch®, AeroText™, ChatEditor™, ChatFusion™, ChatPoint™, ChatSMS®, ChatWrap®, Coaching Corner®, CoreScanner™, Dialogue® AAC, Empower®, Engage®, Essence®, Freedom Switch™, Genesis™, iShare®, iSharePRC®, iShareWFL®, iSurround®, LAMP™, LAMP Words for Life®, Look®, Minspeak®, NovaChat®, NuEye®, NuPoint®, NuVoice®, PASS™, Pixon®, PRC-Saltillo®, PRiO®, Realize Language™, Semantic Compaction®, Timocco-on-Accent™, TouchChat®, Unidad®, Unity®, Unity® AAC, VersaChat®, VersaEye®, VersaSpeaker®, VersaWrap®, Via®, VocabPC™, and Xtreme™ are trademarks of PRC-Saltillo.
Australia
AAC Learning Journey™, Accent™, ChatSMS®, Coaching Corner®, Dialogue™, Empower™, Engage™, Genesis™, LAMP Words for Life®, Liberator Rugged®, Minspeak™, NovaChat®, NovaRugged®, Semantic Compaction®, TouchChat®, Unity™, VersaEye®, VersaSpeaker®, VersaWrap®, Via™
Canada
AAC Language Lab™, AAC Learning Journey®, Accent™, Coaching Corner®, Dialogue® AAC, Empower®, Engage®, Genesis™, LAMP Words for Life®, Minspeak®, NovaChat®, PRC-Saltillo®, Semantic Compaction®, TouchChat®, Unity®, VersaEye®, VersaSpeaker®, VersaWrap®, Via®
European Union
AAC Language Lab™, AAC Learning Journey®, Accent®, AeroSwitch™, Coaching Corner®, Dialogue™, Empower®, Engage®, Genesis™, LAMP Words for Life®, Look™, Minspeak®, NovaChat®, PRC-Saltillo™, Semantic Compaction®, TouchChat®, Unity ™, VersaEye®, VersaSpeaker®, VersaWrap®, Via®
Germany
Accent®, AeroSwitch™, ChatSMS™, Eloquence™, Empower®, Engage™, Genesis™, LoGoFoXX®, LAMP Words for Life™, Look™, Minspeak®, MultiFoXX®, NovaChat™, Quasselkiste™, RehaFoXX®, Via®, WORTSTRATEGIE®
Singapore
AAC Language Lab®, AAC Learning Journey®, Accent™, Coaching Corner™, Dialogue™, Empower™, Engage™, Genesis™, LAMP Words for Life®, Minspeak®, NovaChat®, PRC-Saltillo™, Semantic Compaction®, TouchChat®
United Kingdom
AAC Coaching Corner®, AAC Language Lab®, AAC Learning Journey®, Accent®, AeroSwitch™, ChatSMS®, Coaching Corner™, Dialogue® AAC, EasyChat®, Empower®, Engage®, Essence®, Genesis™, iShare-PRC™, LAMP Words for Life®, Liberator® (logo), Liberator Rugged™, Libswitch™, Look™, Minspeak®, NovaChat®, NuPoint™, NuVoice™, Pixon®, PRC-Saltillo®, Semantic Compaction®, TouchChat®, Unidad®, Unity®, VersaEye®, VersaSpeaker®, VersaWrap®, Via®
Third Parties
Acapela Group® and my-own-voice™ are trademarks of Acapela Group. Acapela Group, Copyright 2026. All rights reserved. Used with permission. The Acapela text to speech technology and the synthetic voices contained in this software are included free of charge for the usage by the end user but may be used solely for communication purposes and may not be sold, copied or otherwise exploited for any type of profit.
AirDrop®, App Store®, Apple®, Apple Books®, Apple Intelligence™, FaceTime®, Guided Access®, iCloud®, iPad®, iPad Air®, iPad mini®, iPadOS®, iPad Pro®, iPhone®, iPod®, iTunes®, Lightning®, Mac®, Macintosh®, Safari®, Siri®, TouchID®, and TrueDepth® are trademarks of Apple Inc., registered in the U.S. and other countries and regions.
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by PRC-Saltillo is under license.
CAVIWIPES™ is a trademark of Metrex Research LLC.
Dropbox® is a registered trademark of Dropbox, Inc.
Google™, Google Docs™, Google Drive™, Google Play™, Android™, Chromebook™, Gmail™, and YouTube™ are trademarks of Google Inc.
Intel®, the Intel logo, Intel® Core™, and Celeron® are trademarks of Intel Corporation or its subsidiaries.
iOS® is a trademark or registered trademark of Cisco in the U.S. and other countries and is used under license.
Ivona is supplied by ReadSpeaker.
METACOM Symbols © Annette Kitzinger. Reservation of Use pursuant to § 44b, paragraph 3, sentence 1 of the German Copyright Act - “No text or data mining”
Microsoft® and Windows® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
My QuickChat™ is copyright of Talk To Me Technologies.
Netflix® is a trademark of Netflix, Inc.
PCS® is a trademark of Tobii Dynavox LLC. All rights reserved. Used with permission.
Samsung® and Galaxy Tab® are registered trademarks of Samsung Electronics America, Inc.
The symbols used in this work are owned by n2y, LLC. Used with permission under license. © 2026.
TIK TOK is a trademark of Bytedance Ltd.
Velcro® is a registered trademark of Velcro BVBA.
VocaliD™ is a trademark of VocaliD, Inc.
The Voice Keeper and Almagu voices are intellectual property of Almagu.
WHATSAPP is a trademark of WHATSAPP LLC.
Wi-Fi® is a registered trademark of Wi-Fi Alliance.
Windex® is a registered trademark of S. C. Johnson & Son, Inc.
WordPower® is a trademark of Inman Innovations, Inc. © 2001-2026; All rights reserved. Used with permission.
Other trademarks are the property of their respective owners.
Specifications: Accent-1400
Classifications
Electrical shock protection: Class II / internally powered
Ingress protection rating: IP22
Mode of operation: Continuous
Type of applied part: BF
Specifications
Weight: 5.9 lbs. with handle, stand, and device frame
Dimensions: 14.1 in. wide × 8.9 in. high × 1.8 in. deep
Display: 14 in. diagonally, screen resolution 1920 x 1080 dpi, viewing angle of 170 degrees or more, capable of 300 nits brightness or greater
Battery life: Ranges from 13 to 15 hours, depending on individual usage and power settings; 10 to 12 hours with eye tracking
Memory and Storage: 8GB RAM, 16GB internal memory card, 128GB external micro SD card slot, 256GB hard drive
Processor: Intel Core i5-7Y54
Operating system: Microsoft Windows 11 Pro
Charger: The following charger is compatible with the device: Megmeet MANGO60S-18BB-PRC (available from PRC-Saltillo). Use only this charger to charge the device.
Standard components: Frame, handle, wire stand, battery charger, USB flash drive, stylus
Accessories: Carry case, carry straps, screen protectors, external power pack, QRM mounting plate, device mounting brackets, keyguards, TouchGuides, replacement frame, eye tracking module, head tracking module
Operating Environment
Note: The device needs to be protected from moisture during use.
Ambient temperature: 0°C to 40°C or 32°F to 104°F
Relative humidity: 10% to 90%
Atmospheric pressure: 80 kPa to 106 kPa
Transport and Storage Environment
While in transport or storage, the range of temperatures to which the device can be exposed is -20°C to 60°C (-4°F to 140°F), with an atmospheric prescription range of 80 kPa to 106 kPa.
Conditions for Safe Contact - Time
Maximum safe contact time for each accessible part while the device is in use (ambient temperature 40°C or 104°F)
Touchscreen: Less than 1 minute
Power button: Less than 1 minute
Volume button: Less than 1 minute
Conditions for Safe Contact - Temperature
Maximum Temperature while Device is in use (ambient temperature 40°C or 104°F)
Touchscreen: 54.3°C or 129.74°F
Power button: 50.5°C or 122.9°F
Volume button: 41.2°C or 106.16°F
⚠ While the device is charging, touching the surface of the device with broken skin may aggravate a wound.
⚠ While the device is charging, infants or high-risk groups should not touch the surface of the device if there is a chance of burning the skin.