--- title: "Setting Up Head Tracking in Empower" slug: "setting-up-head-tracking-in-empower" updated: 2026-09-20T19:38:08Z published: 2026-09-20T19:38:08Z canonical: "documentation.prc-saltillo.com/setting-up-head-tracking-in-empower" --- > ## Documentation Index > Fetch the complete documentation index at: https://documentation.prc-saltillo.com/llms.txt > Use this file to discover all available pages before exploring further. # Setting Up Head Tracking in Empower ## Head Tracking Selection Settings Select **Menu** > **Toolbox** > **User Settings** > **Access Method**. Touch will be selected by default. Select **Change Access Method** to open the Access Methods window. Select **Head Tracking & USB Input**. Once you select head tracking as the access method, (a) head tracking will be active and all settings for that user will take effect immediately, and (b) the Head Tracking & USB Input window will display the head tracking settings on the **Selection** tab. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/Empower-HeadTracking01-Selection01-DwellTab-en-us.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=iv1o%2BkaxQdNvvkHkziJSNIS3e2xFPgtzBDeFoaixucQ%3D) Two methods are available for activating a button. **Dwell** Select a button by dwelling on it. Buttons are selected automatically according to the Dwell Time you choose. **Switch** The user moves the cursor with his or her head and makes selections by activating a switch. Use the slider to adjust switch selection time. **Finished** After making your selections, select **Finished**. **Change Access Method** Switch to a different access method. --- ## Setting Up Dwell Selection **Selection Type** In the Head Tracking & USB Input window, with the Selection tab selected, select the Dwell tab. When Dwell is selected, you can select a button by dwelling on it. Buttons are selected automatically according to the dwell time you choose. **Dwell Time** Dwell time is the amount of time you need to hold your head position to keep the cursor or pointer focused on a button to select it. For example, when dwell time is set to 0.5, a button is selected when you point at it for a half-second. Selectable numbers range from 0.0 to 10.0 seconds. --- ## Setting up Switch Selection In the Head Tracking & USB Input window, with the Selection tab selected, select the Switch tab. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(151).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=Iv7fBLmImI6WTgVtnpQAnK2TXWDMKodoMjJx3Vb1yA4%3D) **Switch Selection Time** Adjust how long you must hold the switch to make a selection. Selection time ranges from 0 to 10 seconds. **Next Switch Selection Delay** Adjust how long you must wait after releasing the switch before you can select another button. Selection delay ranges from 0 to 10 seconds. **Finished** After making your selections, select **Finished**. **Change Access Method** Switch to a different access method. --- ## Pausing and Resuming Head Tracking When head tracking is the current access method, a Tracking is ON/Tracking is OFF dropdown appears at the top of the screen. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(152).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=8VEgNAcjofjIg7610IwIqbryZiqMfoKmdIlXERaNFs4%3D) ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(153).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=btTItXzLWfPamVENQWBMB6N0SoHsAUyqm19423oEO%2Bg%3D) When head tracking is active, the button shows “Tracking is ON”. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(154).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=mhzYFTTliSWnm%2B%2BieDyAVKF3Fq7f9iq4r%2F3cbixPbHM%3D) When you select the “Tracking is ON” button, “Pause” is displayed. To pause head tracking, select **Pause**; the button changes to “Tracking is OFF”. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(155).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=U%2BHTM4L6dB20Ki7tcCIMg2jhr9Jke%2BMr8iq3%2FJDO9Co%3D) When head tracking is paused, the button shows “Tracking is OFF”. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(156).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=Ti0nlTOS%2F5TITS3hXqnISMJThJEU4kKtlxmX1w%2BuaL0%3D) When you select the “Tracking is OFF” button, “Resume” is displayed. To resume head tracking, select Resume; the button changes to “Tracking is ON”. **Note:** When Tracking is OFF, the cursor will still be visible on the screen and follow the user’s head movements. However, no selections can be made other than selecting Resume. --- ## Additional Head Tracking Settings From the Head Tracking & USB Input window, select Settings. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(157).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=hZGM0RfKzjCBtAxYUfJLh4iy6lz62mJfdRlo5caz%2F%2BI%3D) **Text Field Keyboard in Edit Mode** When Text Field Keyboard in Edit Mode is turned on, a keyboard will appear when you select a text field in edit mode. You do not need to select the keyboard icon. When Text Field Keyboard in Edit Mode is turned off, you must select the keyboard icon to display the keyboard. **Pause/Resume Dropdown** Show or hide the Tracking is ON/Tracking is OFF dropdown. When the Pause/Resume Dropdown option is turned on ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(159).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=%2Bg%2FLN%2BKljO1YGszQke6pg%2Fx7EKkLPu6ymccLan%2BRKEc%3D), the Tracking is ON/Tracking is OFF dropdown will appear at the top of the screen when head tracking is active. When the Pause/Resume Dropdown option is turned off ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(160).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=37zayCz8Gz9nynrM2AFS5TXqI4KNUbYuUUDQodjtcV4%3D), the Tracking is ON/Tracking is OFF dropdown will not appear at the top of the screen when head tracking is active. **Finished** After making your selections, select **Finished**. **Change Access Method** Switch to a different access method. --- ## Calibrating the Cursor For the most part, when idle and the user is centered and parallel to the screen, the cursor should be in the center of the screen. If the cursor settles too high or low or too far left or right, it needs to be calibrated. In addition, if you feel as though you are straining to reach a target at the top, bottom, right, or left edges of the screen, the cursor needs to be calibrated. From the Head Tracking & USB Input window, select **Tracking**. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(161).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=Zl8v%2FSLcWWQ2M15LVxVXo9fLIYgZ54jyYsf1XLpGew0%3D) **Smoothing** Increase smoothing to reduce the amount of cursor jitter and slow down cursor speed. Selectable values range from 1.0 to 10.0. **Vertical Adjust** Use Vertical Adjust to adjust the sensitivity of the cursor along the vertical axis. Increase the Vertical Adjust setting to make the cursor more responsive to small up and down movements of the head. 0 is visually the “slowest” setting and 10 the “fastest”. A low Vertical Adjust setting (for example, 1) means you need larger head movements to move the cursor (greater range of motion). A high Vertical Adjust setting (for example, 10) means smaller head movements will move the cursor (limited range of motion). **Horizontal Adjust** Use Horizontal Adjust to adjust the sensitivity of the cursor along the horizontal axis. Increase the Horizontal Adjust setting to make the cursor more responsive to small left-to-right and right-to-left movements of the head. 0 is visually the “slowest” setting and 10 the “fastest”. A low Horizontal Adjust setting (for example, 1) means you need larger head movements to move the cursor (greater range of motion). A high Horizontal Adjust setting (for example, 10) means smaller head movements will move the cursor (limited range of motion). **Cursor Calibration Type** Select the type of calibration based on the user’s capabilities with head movements. **Default:** Select Default if the user can reliably align head movements with the cursor. **Centered:** Select Centered if the user is unable to align head movements with the cursor. **Calibrate** **Note:** The Calibrate button is only available when Centered is selected. When you have adjusted the settings, select the **Calibrate** button to begin the calibration process. --- ## Using the Default Calibration The Default calibration is extremely flexible with regards to positioning changes. As an individual’s position changes, the default calibration allows the user to realign the cursor on-the-fly to accommodate the change. Align the cursor at an edge of the screen. Default calibration is best explained using an example. If the cursor feels as though its resting position is too far to the left, align your head with the cursor at the left edge of the screen to re-center the cursor. Conversely, if the cursor feels too far to the right, align your head with the cursor at the right edge of the screen to re-center the cursor. This same principle applies when realigning on the vertical axis. --- ## Using the Centered Calibration The Centered calibration will adjust the position of the cursor so that it is centered with respect to the user’s current head position. If your orientation or position changes, you may need to re-center the cursor. For example, a device is mounted slightly to the left of the user on a wheelchair. Because of this, when the user looks straight ahead, the cursor may appear shifted to the right. To compensate for this, have the user position his or her head at a comfortable, natural starting position and then select **Centered**. When you select **Calibrate**, the cursor is hidden temporarily and an image appears in the center of the screen. Have the user look at the image until the image disappears (after three seconds). The cursor will be centered. 1. For Cursor Calibration Type, select Centered. This will force the user to perform a calibration. After the first calibration, you can calibrate again by selecting the **Calibrate** button. 2. The Center Cursor Calibration window will open. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(162).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=W9h7YiN8wn5gd%2FMSWy9HjRzid1WkYPwm1jPqiEQnqFo%3D) 3. Look at the center of the device screen. When you are ready, select **Calibrate**. 4. The centering image will appear in the center of the screen for approximately three seconds. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(163).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=yeKgNq0ujMkJvmkgb7eTS5W1r8htWx5wq%2FmYqMJh%2BHs%3D) 5. During this time, the device will record the user’s position (the reflective dot) and automatically center the cursor. After three seconds, the “Calibration complete!” screen will appear. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(164).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=w%2B9RWMl9S8cL9BVd%2BFeajJHezEYv0s9S7lbHoJyIcx0%3D) 6. Test the calibration by moving the cursor to each target on the screen. - If you are able to reach the targets easily, select **Finished**. - If you have difficulty reaching the targets, select **Recalibrate** and try again. 7. If you still have difficulty reaching the targets, select **Finished** and adjust the Horizontal Adjust or Vertical Adjust settings. Then calibrate again. 8. When the calibration process is complete, you will be taken back to the Head Tracking & USB Input menu. 9. Select **Finished**. --- ## Recalibrating the Cursor by Using a Vocabulary Button If you want to be able to recalibrate the head tracking cursor by choosing a button in your vocabulary, set up the Head Tracking Calibration action on a button. 1. Select **Menu > Editor**. 2. Navigate to the button where you want to place the calibration button. 3. Select **Edit** and choose the button. 4. Select the **Actions** tab on the left. The Action List is displayed. 5. Select **Add Action**. Action categories are listed. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(165).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=%2BnYoB5mtBlFqYRTHw4XVML73cwETfgJ%2FVvME56ObuJc%3D) 6. Select **Access Method Functions**. 7. Select the Head Tracking Calibration **Choose** button. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(166).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=IalQ7ZrAImeOmXs%2BpbtbRokCeu%2BRY0dLGYdZgyVy4mw%3D) 8. Select **Finished**. The action will be added to the button. **Before using your calibration button:** After you add the Head Tracking Calibration action to a button, you can calibrate the cursor only if the following conditions have been met. - Access Method is set to Head Tracking & USB Input - Cursor Calibration Type is set to Centered - Tracking is ON **To calibrate the cursor using your calibration button:** 1. Go to the vocabulary page that includes the button you set up for calibration. 2. Select the button. 3. Follow the procedure under “Calibrating the Cursor”. 4. When the calibration process is complete, you will be taken back to where you were in your vocabulary. --- ## Adding a Tracking Shortcut When head tracking is the current access method and you have turned off the Pause/Resume Dropdown setting, you can use the Tracking shortcut to quickly toggle head tracking on or off from the Quick Menu. 1. Select **Menu** to open the Quick Menu. 2. Select **Modify Shortcuts**. 3. Select the space to which you want to add the Tracking shortcut. The space will change color. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(167).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=IqzyYVBBo%2BCgTKYbsHiTFL4SsPRgmgMswV11tdmA8TM%3D) 4. Select the **Tracking** shortcut. The shortcut will appear in the selected space. ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/image(168).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A08%3A29Z&se=2026-11-20T05%3A08%3A29Z&sr=b&sp=r&sig=ftCUOlo22KutjYteLkDBfb13M6nAxxClAi7nKWBmyIQ%3D) 5. Select **Save**. The Tracking shortcut will show “Tracking is OFF” or “Tracking is ON” in the Quick Menu any time you select the Menu button. Select the shortcut to toggle the setting on or off.