--- title: "Empower: Setting Up Head Tracking" slug: "empower-setting-up-head-tracking" updated: 2026-08-11T12:47:52Z published: 2026-08-11T12:47:52Z canonical: "documentation.prc-saltillo.com/empower-setting-up-head-tracking" --- > ## Documentation Index > Fetch the complete documentation index at: https://documentation.prc-saltillo.com/llms.txt > Use this file to discover all available pages before exploring further. # Empower: Setting Up Head Tracking > [!NOTE] > **Note:** Accent devices ship with two software options: Empower or NuVoice. For information on how to use head tracking with NuVoice software, see “NuVoice: Setting Up Head Tracking.” To use head tracking to control your device, go to **Menu** > **Toolbox** > **User Settings** > **Access Method** > **Head Tracking & USB Input**. Once you select head tracking as the access method, head tracking is active and all settings for that user take effect immediately. ## Head Tracking Selection Settings Go to **Menu** > **Toolbox** > **User Settings** > **Access Method** > **Head Tracking & USB Input**. The Head Tracking & USB Input window displays the head tracking settings on the **Selection** tab. ![The Access Methods window shows the Selection tab and Dwell selection type selected and the Dwell Time set to 1.0.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-kygd6cjp.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=kWDI%2Fz4vav883CID7xY%2FP%2BXYeSkVk217oaQd3DhQL08%3D) Two methods are available for activating a button. **Dwell:** Select a button by dwelling on it. Buttons are selected automatically according to the Dwell Time you choose. **Switch:** The user moves the cursor with his or her head and makes selections by activating a switch. Use the slider to adjust switch selection time. ### Setting up Dwell Selection #### Selection Type In the Head Tracking & USB Input window, with the **Selection** tab selected, select the **Dwell** tab. When Dwell is selected, you can select a button by dwelling on it. Buttons are selected automatically according to the dwell time you choose. #### Dwell Time Dwell time is the amount of time you need to hold your head position to keep the cursor or pointer focused on a button to select it. For example, when dwell time is set to 0.5, a button is selected when you point at it for a half-second. Selectable numbers range from 0.0 to 10.0 seconds. ### Setting up Switch Selection In the Head Tracking & USB Input window, with the **Selection** tab selected, select the **Switch** tab. ![The Access Methods window shows the Selection tab and Dwell selection type selected and the Dwell Time set to 1.0.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-fyu4frni.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=MEVsy1o%2BzInvfh6EDRlIhSLENcCP0%2BmWMFad7rc7Vxw%3D) #### Switch Selection Time Adjust how long you must hold the switch to make a selection. Selection time ranges from 0 to 10 seconds. #### Next Switch Selection Delay Adjust how long you must wait after releasing the switch before you can select another button. Selection delay ranges from 0 to 10 seconds. --- ## Additional Head Tracking Settings Go to **Menu** > **Toolbox** > **User Settings** > **Access Method** > **Head Tracking & USB Input**. The Head Tracking & USB Input window displays the head tracking settings. Select **Settings**. ![The Access Methods window shows the Settings tab selected, Text Field Keyboard in Edit Mode turned off, and Pause/Resume Dropdown turned on.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-bo8c6k6d.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=R8sTalRMiljx8HCzu96FbQG3U1uZ%2FMsw7wXbo3cOhrg%3D) #### Text Field Keyboard in Edit Mode When Text Field Keyboard in Edit Mode is on, a keyboard will appear when you select a text field in edit mode. You do not need to select the keyboard icon. When Text Field Keyboard in Edit Mode is off, you must select the keyboard icon to display the keyboard. ![An example of a text field shows an "Enter Word" prompt and a keyboard icon.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-hiro4eqq.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=CF4WpqYPAuF2g%2FfeaVxqW2FFReVLa1m58%2Ftheq4xBwU%3D) --- ## Pausing and Resuming Head Tracking When head tracking is the current access method, a Tracking is ON/Tracking is OFF dropdown appears at the top of the screen. ![An arrow points out the location of the Tracking On/Off dropdown.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-uisu5m6w.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=WoEFpV2RhO4TuXqiabxXROrDylMwn%2BtjxAhRiRHRY5Y%3D) ![Tracking is on](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-udok2hli.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=CQSAb3g8wwQcV2hrgh82jk6FCGSTiBWcMaajv7WdZ8M%3D) When head tracking is active, the button shows “Tracking is ON”. ![Pause](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-4mqpegnf.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=dJ4oDeuD1omSWTWMuVcQdEUcgni0pYrbqxavI%2BzAGk0%3D) When you dwell on the button, “Pause” is displayed. To pause head tracking, select **Pause**; the button changes to “Tracking is OFF”. ![Tracking is off](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-x1oxg3lh.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=%2BsFtT6DcyDMqYwyrMRyOw2MVHd5rcfTQNc659uzh21E%3D) When head tracking is paused, the button shows “Tracking is OFF”. ![Resume](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-oo0u32tj.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=veY0uYHotsAzTgX7hHAm1TB%2FF2VPhwnLkk0cN7UZF7o%3D) When you dwell on the button, “Resume” is displayed. To resume head tracking, select **Resume**; the button changes to “Tracking is ON”. When you want to pause head tracking but still be able to make menu selections with a finger, select **Pause**. Select **Resume** to resume using head tracking. To show or hide the Tracking is ON/Tracking is OFF dropdown, go to **Menu** > **Toolbox** > **User Settings** > **Access Method** > **Head Tracking Settings** and then select the **Settings** tab. Select the Pause/Resume Dropdown toggle to turn the dropdown on ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-imz3hwld.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=LeJqaU0Su2%2BTgvJBjfQaqVbXPgtGhpRm3OaD3mwG3gY%3D) or off ![](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-7c1homnw.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=%2BHNtNmsxMmgtGUDYb9ZvaQ2ablbEkghdwWC34mOXcJI%3D). --- ## Calibrating the Cursor For the most part, when idle and the user is centered and parallel to the screen, the cursor should be in the center of the screen. If the cursor settles too high or low or too far left or right, it needs to be calibrated. In addition, if the user is straining to reach a target at the top, bottom, right, or left edges of the screen, the cursor needs to be calibrated. ### Using the Default Calibration The Default calibration is extremely flexible with regards to positioning changes. As an individual’s position changes, the default calibration allows the user to realign the cursor on-the-fly to accommodate the change. Align the cursor at an edge of the screen. Default calibration is best explained using an example. If the cursor feels as though its resting position is too far to the left, align your head with the cursor at the left edge of the screen to re-center the cursor. Conversely, if the cursor feels too far to the right, align your head with the cursor at the right edge of the screen to re-center the cursor. This same principle applies when realigning on the vertical axis. ### Using the Centered Calibration > [!NOTE] > **Note:** This option is only available when using the NuPoint head tracking module. The Centered calibration will adjust the position of the cursor so that it is centered with respect to the user’s current head position. If your orientation or position changes, you may need to re-center the cursor. For example, a device is mounted slightly to the left of the user on a wheelchair. Because of this, when the user looks straight ahead, the cursor may appear shifted to the right. To compensate for this, have the user position his or her head at a comfortable, natural starting position and then select **Centered**. When you select **Calibrate**, the cursor is hidden temporarily and an image appears in the center of the screen. Have the user look at the image until the image disappears (after three seconds). The cursor will be centered. 1. Go to **Menu** > **Toolbox** > **User Settings** > **Access Method** > **Head Tracking & USB Input** and select the **Tracking** tab. 2. For **Cursor Calibration Type**, select **Centered**. This will force the user to perform a calibration. After the first calibration, you can calibrate again by selecting the **Calibrate** button. ![A red box highlights the Cursor Calibration Type option with the Default and Centered settings and the Calibrate button.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-hj6feyx9.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=%2F8f5h%2BD62LEK66ehEcl%2FtbjLhXoBQQRQjAsMNRRy5r8%3D) 3. The Center Cursor Calibration window will appear. ![The Center Cursor Calibration window provides Calibrate and Cancel buttons.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-6lj8eqjy.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=FAiEmqf%2BFCMzlwxmTtghg29%2BvP7%2Fdyw%2BZkWbgRmCCX4%3D) 4. Look at the center of the device screen. When you are ready, select **Calibrate**. 5. The centering image will appear in the center of the screen for approximately three seconds. ![The centering image looks similar to a piece of starlight peppermint mint hard candy.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-1u0c7jgp.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=ely5UWhySo%2FB2Gbky9B9kt6%2FxI31g%2BypuuJbZmbripE%3D) 6. During this time, the device will record the user’s position (the reflective dot) and automatically center the cursor. After three seconds, the “Calibration complete!” screen will appear. ![The Calibration Complete screen features four target images, a Finished button, and a Recalibrate button.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-1fqlobgl.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=WErBYXkuxexk0WpyU0Z6MqX6f4r8UFO5pqkuc1O9U64%3D) 7. Test the calibration by moving the cursor to each target on the screen. - If you are able to reach the targets easily, select **Finished**. - If you have difficulty reaching the targets, select **Recalibrate** and try again. 8. If you still have difficulty reaching the targets, select **Finished** and adjust the Horizontal Adjust or Vertical Adjust settings. Then calibrate again. 9. When the calibration process is complete, you will be taken back to the Head Tracking & USB Input menu. ### Recalibrate the Cursor with a Button Action If you want to be able to recalibrate the head tracking cursor by choosing a button in your vocabulary, set up the Head Tracking Calibration action on a button. #### To add the Head Tracking Calibration action to a button: 1. Select **Menu** > **Editor**. 2. Navigate to the button where you want to place the calibration button. 3. Select **Edit** and choose the button. 4. Select the **Actions** tab on the left. The Action List is displayed. 5. Select **Add Action**. Action categories are listed. ![The Edit Button window shows the Actions tab selected and the Action categories listed.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-zrxsm16r.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=LhGu5f3670sSF591OpSdcX4GnKiVV6faHz77h%2F5C0dk%3D) 6. Select **Access Method Functions**. 7. Select the Head Tracking Calibration **Choose** button. ![The Edit Button window shows the actions tab selected and Head Tracking Calibration in the Actions List.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-s1ffjqmd.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=hGdCmqSgOTZfh9llLZXk644QrDBND%2FtHGEoUJK6PZOA%3D) 8. Select **Finished**. The action will be added to the button. #### Before using your calibration button: After you add the Head Tracking Calibration action to a button, you can calibrate the cursor only if the following conditions have been met. - NuPoint module is installed - Access Method is set to Head Tracking & USB Input - Cursor Calibration Type is set to Centered - Tracking is ON #### To calibrate the cursor using your calibration button: 1. Go to the vocabulary page that includes the button you set up for calibration. 2. Select the button. 3. Follow the procedure in [Calibrating the Cursor](/documentation/docs/empower-setting-up-head-tracking#calibrating-the-cursor). 4. When the calibration process is complete, you will be taken back to where you were in your vocabulary. --- ## Adding a Head Tracking Shortcut When head tracking is the current access method and you have turned off the Pause/Resume Dropdown setting, you can use the Tracking shortcut to quickly toggle head tracking on or off from the Quick Menu. 1. Select **Menu** to open the Quick Menu. 2. Select **Customize Quick Menu**. 3. Select the space to which you want to add the Tracking shortcut. The space will change color. ![The Quick Menu shows the selected space.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-3jhatwxy.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=PjDUnRe77ZxS3LQMcD6B7XR%2BWmQG%2FbB5Reu9%2F4OTGck%3D) 4. Select the **Tracking** shortcut. The shortcut will appear in the selected space. ![The Quick Menu shows the shortcut in the selected space.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-colxdm2o.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=NQyrGdUvijsydDM8nOBCUqI0DVoUkklGzZWlYXcrNHw%3D) 5. Select **Save**. The Tracking shortcut will show “Tracking is OFF” or “Tracking is ON” in the Quick Menu any time you select the **Menu** button. Select the shortcut to toggle the setting on or off. --- ## Adjusting Head Tracking Settings Go to **Menu** > **Toolbox** > **User Settings** > **Access Method** > **Head Tracking & USB Input**. The Head Tracking & USB Input window displays the head tracking settings. Select **Tracking**. ![An example of the Access Methods window shows the following selections: the Tracking tab, the Smoothing value set to 2.0, Vertical and Horizontal Adjust values set to 5.0 each, and the Cursor Calibration Type set to Centered.](https://cdn.document360.io/7e1d5036-9a43-443d-8ea7-a17280ea302d/Images/Documentation/setting-up-head-tracking-in-empower-image-l8ws9rz7.png?sv=2026-02-06&spr=https&st=2026-11-24T06%3A21%3A58Z&se=2026-11-24T07%3A21%3A58Z&sr=b&sp=r&sig=i8nRadASLr2ArKlEIUEMkTAm22FlV6VKKwGbH5QozS0%3D) #### Smoothing Increase smoothing to reduce the amount of cursor jitter and slow down cursor speed. Selectable values range from 1.0 to 10.0. #### Vertical Adjust Use Vertical Adjust to adjust the sensitivity of the cursor along the vertical axis. Increase the Vertical Adjust setting to make the cursor more responsive to small up and down movements of the head. 0 is visually the “slowest” setting and 10 the “fastest”. A low Vertical Adjust setting (for example, 1) means you need larger head movements to move the cursor (greater range of motion). A high Vertical Adjust setting (for example, 10) means smaller head movements will move the cursor (limited range of motion). #### Horizontal Adjust Use Horizontal Adjust to adjust the sensitivity of the cursor along the horizontal axis. Increase the Horizontal Adjust setting to make the cursor more responsive to small left-to-right and right-to-left movements of the head. 0 is visually the “slowest” setting and 10 the “fastest”. A low Horizontal Adjust setting (for example, 1) means you need larger head movements to move the cursor (greater range of motion). A high Horizontal Adjust setting (for example, 10) means smaller head movements will move the cursor (limited range of motion). #### Cursor Calibration Type Select the type of calibration based on the user’s capabilities with head movements. **Default:** Select Default if the user can reliably align head movements with the cursor. **Centered:** Select Centered if the user is unable to align head movements with the cursor. #### Calibrate > [!NOTE] > **Note:** The Calibrate button is only available when Centered is selected. When you have adjusted the settings, select the Calibrate button to begin the calibration process. --- ## Empower Settings to Enhance Head Tracking You may find that adjusting additional Empower settings will help the head tracking experience. ### Cursor Feedback for Head Tracking Adjust the appearance of the cursor. Go to **Menu** > **Toolbox** > **User Settings** > **Cursor, Dwell & Selection Feedback** > **Cursor**. **Cursor:** When Cursor is turned on, a real-time cursor appears on the screen in the shape of an arrow or hand. The default setting is on. **Cursor Size:** Choose S (small), M (medium), or L (large). **Cursor Color:** Select the Colors tab on the left side of the window and set the color of the cursor. ### Dwell Feedback for Head Tracking Adjust what you see when you dwell on a button. Go to **Menu** > **Toolbox** > **User Settings** > **Cursor, Dwell & Selection Feedback** > **Dwell Feedback**. **Pointer:** The pointer is an on-screen indicator that shows what button the user is pointing to. Choose None, Circle, or Square. The default is None. **Pointer Size:** Choose a number between 1 and 10. **Pointer Animation:** Choose None or Shrink. **Pointer Color:** Select the Colors tab on the left side of the window and set the color of the pointer. **Dwell Feedback:** Set how a button looks when you dwell on it. Choose None, Invert, Border, or Fill. ### Selection Feedback for Head Tracking Adjust what happens when you select a button. Go to **Menu** > **Toolbox** > **User Settings** > **Cursor, Dwell & Selection Feedback** > **Selection Feedback**. **Selection Feedback:** To see a visual indication when a button is selected, select Invert, Border, or Fill. **Beep:** To hear a beep when a button is selected, turn Beep on. ### Button Padding for Head Tracking Padding provides additional space between buttons. 1. Go to **Menu** > **Toolbox** > **Vocabulary** > **Vocabulary Settings**. 2. Select the **Button Preferences** tab. 3. Set Button Padding (the space between buttons) as a percentage from 0% to 40%. ### Adjust Action of Blank Buttons for Head Tracking Choose how buttons with no content act. 1. Go to **Menu** > **Toolbox** > **Vocabulary** > **Vocabulary Settings**. 2. Select the **Button Preferences** tab. 3. Set Empty Button Action as either **No Action** or **Go To Home**.